Bulletin of Surveying and Mapping ›› 2021, Vol. 0 ›› Issue (3): 7-11,17.doi: 10.13474/j.cnki.11-2246.2021.0069

Previous Articles     Next Articles

Accuracy analysis of BDS-3 dual frequency combination precision point positioning

LIU Shengfeng1, YANG Wenlong1, GU Tao2   

  1. 1. China Ordnance Industry Test and Research Institute, Huayin 714200, China;
    2. Northern Electronics Research Institute Co., Ltd., Xi'an 710000, China
  • Received:2020-04-13 Online:2021-03-25 Published:2021-04-02

Abstract: In view of the difference in the precise point positioning performance of different dual-band combinations of BDS-2, BDS-3, and BDS-2/BDS-3, this paper analyzes the PPP precision of seven different dual-band combinations in BDS-3 and compares it with BDS-2, BDS-2/BDS-3 same frequency dual frequency combination PPP precision comparison. The results show that the precision of BDS-2 and BDS-3 at the same frequency dual-frequency combination PPP is equivalent to the first convergence time. Among them, the precision of B2I/B3I combination PPP is the worst, and the precision of BDS-2/BDS-3 positioning precision and the first convergence time compared with the single situation, it has been greatly improved. In terms of BDS-3 dual-band combined PPP, the precision and first convergence time of the B2b/B3I combined PPP are the worst of the BDS-3 seven dual-band combined PPP, and the positioning performance of the other six dual-band combined PPPs is comparable.

Key words: BDS-3, precise point positioning, dual frequency, precision, convergence time

CLC Number: